Добрый день! Коллеги подскажите почему не поднимается кластер:
# cphaprob stat
Cluster Mode:   High Availability (Active Up) with IGMP Membership
ID         Unique Address  Assigned Load   State          Name
1 (local)  
169.254.9.37    0%              DOWN           FFRP-GW1
2          
169.254.9.38    100%            ACTIVE         FFRP-GW2
Active PNOTEs: FSYNC
Last member state change event:
   Event Code:                 CLUS-110800
   State change:               INIT -> DOWN
   Reason for state change:    Incorrect configuration - Local cluster member has fewer cluster interfaces configured compared to other cluster member(s)
   Event time:                 Sun Jan  4 01:25:03 2009
Cluster failover count:
   Failover counter:           0
   Time of counter reset:      Sun Jan  4 01:24:26 2009 (reboot)
========================================
#cphaprob list
Registered Devices:
Device Name: Fullsync
Registration number: 0
Timeout: none
Current state: problem
Time since last report: 0 sec